-
Tedlar® Gas Sampling Bags
tedlar-gas-sampling-bags
-
Tedlar® Gas Sampling Bags with Screw Cap Combo Valve® with Septum
POLYPROPYLENE SCREW CAP COMBO VALVE WITH REPLACEABLE SEPTUM
- On/Off valve function with a replaceable septum in a single unit is economical.
- Lightweight, making it easier to carry in the field and reduces shipping costs.
- Made of inert polypropylene to ensure purity of sample and non-contamination.
- Quick, easy opening and closing of valve to save time.
- Cap stop limits amount cap can be opened to stop leaks from opening cap too far.
- Visual confirmation that valve is open or closed, prevents accident sample loss.
- No guessing whether valve is open or closed.
- Valve Stem is 3/16" OD with tapered outer end for tubing or compression fitting.
- Replaceable fluoropolymer faced, low bleed septum; allows reuse of valve by replacing inexpensive septum.
- Designed and Manufactured by Jensen Inert Products specifically for gas sampling applications.
-
Tedlar® Gas Sampling Bags with Locking Combo® Valve with Septum
POLYPROPYLENE LOCKING COMBO® VALVE WITH SEPTUM
- On/Off valve function with septum in a single unit is economical.
- Lightweight, making it easier to carry in the field and reduces shipping costs.
- Made of inert polypropylene to ensure purity of sample and non-contamination.
- Push/Pull (On/Off) valve stem for quick, easy opening and closing of valve (< 1 second).
- Faster than "twist action" valves.
- Quick locking function, in closed position. Locked position is easy to verify visually, and prevents accidental sample loss during shipment
- Virtually impossible to open or close valve too far
- Valve Stem is 3/16" diameter
- Fluoropolymer faced septum, with Ultra-low bleed silicone, prevents contamination and is located in base flange of valve with bag film below, so septum does not come into contact with sample inside bag.
- Septum allows repeated punctures with syringes without leakage
- Designed, Patented and Manufactured by Jensen Inert Products specifically for gas sampling applications.
-
Tedlar® Gas Sampling Bags with Nickel Plated HR® ON/OFF Valve with 1/4" Diameter Barbed Stem
NICKEL PLATED HR® ON/OFF VALVE WITH 1/4" DIAMETER BARBED STEM
- Nickel Plated to resist damage from most aggressive chemicals.
- 1/4" Barbed Stem for attaching tubing, helps keep tubing in place.
- Leak resistant seal in closed position, prevents sample loss. However, when stem is not closed, sample air passes into the ambient air outside valve.
-
Tedlar® Gas Sampling Bags with 1/4" Plastic Jaco® Fitting with Fluoropolymer Faced Septum
PLASTIC JACO® FITTING FOR 1/4" TUBING OR SEPTUM
- Polypropylene molded construction is inexpensive compared to metal fittings.
- Replaceable fluoropolymer faced septum with large area, allows repeated punctures with common lab syringes.
- Allows reuse of valve by only replacing septum.
- Option of cap with septum or cap for use with tubing.
- Allows syringe sample extraction or attachment of tubing by changing caps
- Compression ferrule secures tubing onto fitting, which provides a superior grip compared to metal fittings
- Standard Jaco can be used with 1/4" tubing. Jaco for 1/2" and 3/8" tubing also available
-
Tedlar® Gas Sampling Bags with 3/8" Plastic Jaco® Fitting with Fluoropolymer Faced Septum
PLASTIC JACO® Fitting for 3/8" Tubing or Septum
- Polypropylene molded construction is inexpensive compared to metal fittings.
- Replaceable fluoropolymer faced septum with large area, allows repeated punctures with common lab syringes.
- Allows reuse of valve by only replacing septum.
- Option of cap with septum or cap for use with tubing.
- Allows syringe sample extraction or attachment of tubing by changing caps
- Compression ferrule secures tubing onto fitting, which provides a superior grip compared to metal fittings
- Jaco® can be used with 3/8" tubing. Jaco® for 1/2" and 1/4" tubing also available
-
Tedlar® Gas Sampling Bags with Nickel Plated HR® ON/OFF Valve with 1/4" Diameter Barbed Stem & Separate Plastic 1/4" Jaco® Fitting with Fluoropolymer Faced Septum
NICKEL PLATED HR® ON/OFF VALVE WITH 1/4" DIAMETER BARBED STEM AND SEPARATE PLASTIC JACO® FITTING WITH FLUOROPOLYMER FACED SEPTUM
You get the features of both the HR® Valve and the Jaco® Fitting on one bag
HR® Features:- Nickel Plated to resist damage from most aggressive chemicals
- 1/4" Barbed Stem for attaching tubing, helps keep tubing in place
- Leak resistant seal in closed position, prevents sample loss. However, when stem is not closed, sample air passes into the ambient air outside valve
- Polypropylene molded construction is inexpensive compared to metal fittings
- Replaceable fluoropolymer faced septum with large area, allows repeated punctures with common lab syringes.
- Allows reuse of valve by only replacing septum.
- Option of cap with septum or cap with tubing, allows syringe sample extraction or attachment of tubing by changing caps.
- Compression ferrule secures tubing onto fitting, which provides a superior grip compared to metal fittings.
- Standard Jaco can be used with 1/4" tubing. Jaco for 1/2" and 3/8" tubing also available.
-
Tedlar® Gas Sampling Bags with Stainless Steel Swagelok® Type Fitting for 1/4" O.D. Tubing
STAINLESS STEEL SWAGELOK® TYPE FITTING FOR 1/4" OD TUBING
- Stainless Steel construction provides durability and ability to withstand use in austere sampling conditions.
- Option of cap for tubing or septum, allows attachment of tubing or syringe sample extraction by switching caps
- Replaceable fluoropolymer faced septum with large area, allows repeated punctures with common lab syringes.
- Allows reuse of valve by only replacing septum
-
Tedlar® Gas Sampling Bags for EPA TCLP Method with Single Stainless Steel Septum Fitting
STAINLESS STEEL TCLP FITTING WITH REPLACEABLE SEPTUM
- Stainless Steel body construction with aluminum cap provides durability and withstands use in austere sampling conditions.
- Sample contacts only stainless steel
- Lower cost compared to 1/4" Swagelok® type fittings and Nickel Plated Halkey® Roberts fitting
- Designed for use with Zero Headspace Extractors, validated fitting style for EPA TCLP (Toxicity Characteristic Leaching Procedure) method
-
Tedlar® Gas Sampling Bags with PFA Fitting for 1/4" OD Tubing
PFA FITTING FOR 1/4" OD TUBING OR SEPTUM
- PFA Fluoropolymer construction so sample only comes into contact with high purity, inert PFA, the ultimate in chemical resistance and non-contaminating material
- Option of cap for tubing to allow attachment of tubing or cap with septum to allow syringe sample extraction by changing caps.
- Replaceable fluoropolymer faced septum with large area, allows repeated punctures with common lab syringes.
- Allows reuse of valve by only replacing septum
-
Tedlar® Gas Sampling Bags with PTFE ON/OFF Valve with Stopcock
PTFE ON/OFF VALVE WITH STOPCOCK
- Valve is 100% inert PTFE so sample only comes into contact with PTFE
- Valve stem approximately 1/4" OD for use with 1/4" or 3/16" ID tubing
- Optional septum with cap available
-
Tedlar® Gas Sampling Bags with Single Stainless Steel Push/Pull Valve
SINGLE STAINLESS STEEL PUSH/PULL VALVE
- Stainless Steel construction provides durability and ability to withstand use in austere sampling conditions.
- Push/Pull (On/Off) valve stem for quick, easy opening and closing of valve
- Aluminum collar locked on SS valve body and nut
- 3/16” diameter Stainless Steel stem
-
Tedlar® Gas Sampling Bags with Stainless Steel Push/Pull Valve and Separate Stainless Steel Septum Fitting with Replaceable Septum
STAINLESS STEEL PUSH/PULL VALVE AND SEPARATE STAINLESS STEEL SEPTUM FITTING WITH REPLACEABLE SEPTUM
- This combination of fitting and valve allows for use of Push/Pull valve for tubing and a separate fitting for septum use.
- Stainless Steel construction provides durability and ability to withstand use in austere sampling conditions.
- Replaceable fluoropolymer faced septum, allows repeated punctures with common lab syringes.
- Allows reuse of valve by only replacing septum
- Push/Pull (On/Off) valve stem for quick, easy opening and closing of valve
- Aluminum collar locked on SS valve body and nut+
- 3/16" diameter Stainless Steel stem